SD50-H – Datasheet

  • Version
  • Download 2268
  • File Size 284.96 KB
  • File Count 1
  • Create Date February 9, 2018
  • Last Updated April 9, 2018

SD50-H - Datasheet

SD50-H COMBINES EXTREME DURABILITY AND HIGH
PERFORMANCE TO SERVE AS OUR PREMIER DISPLAY
CONTROLLER FOR MEASUREMENT AND MONITORING
IN HAZARDOUS AREAS. DESIGNED FOR MAXIMUM
CONFIGURATION FLEXIBILITY, SD50-H IS ALSO A NATURAL
CHOICE FOR OEM AND CUSTOM APPLICATIONS.
IN ADDITION TO A VARIETY OF HAZARDOUS AREA
CERTIFICATIONS, SD50-H IMPROVES UPON THE STANDARD SD50
BY INCLUDING A BEZEL WITH ENHANCED SHATTER RESISTANCE
AND TOOL-SAFE CONNECTOR LOCKING TECHNOLOGY.
Features
–– Digital sensor network
–– Manages a network of ≤16 wired or wireless
devices, which include mV/V, mA, quadrature,
digital and a variety of application-specific
sensors.
–– Improved noise immunity insures
measurement fidelity.
–– Simplified network schema reduces cabling
costs and setup time.
–– Advanced Multi-Controller Setup allows seamless
integration of additional LMC or SD50 controllers.
–– Interfaces included Ethernet (TCP/IP, UDP, FTP and
Webserver), RS485 (ASCII or Binary) and USB.
–– SD card slot provides onboard data logging.
–– Internally protected against transient voltages
and polarity reversal.
Electrical Specifications
Voltage DC: 10.5 to 28.0 VDC
Current DC: 1.2 A max
Voltage AC: 120 VAC
Current AC: 0.3 A max
Environmental
Operating Temperature: -40
to 165°F (-40 to 74°C)
Storage Temperature: -40 to
185°F (-40 to 85°C)
Dimensions
Height: 6.56 in (16.66 cm)
Width: 9.56 in (24.28 cm)
Depth: 5.06 in (12.85 cm)
Weight: 17 lbs (7.71 kg)
Enclosure
Material: 316 Stainless Steel
Rating: NEMA 4X, IP66
Certifications
Class I, Division II, Grp C, D T4 (-40°C < Ta < 75°C)
Conforms To: ANSI/ISA 12.12.01, ANSI/UL 61010-1
Certified To: CAN/CSA C22.2 No. 61010-1,
CAN/CSA C22.2 No. 213